This module is designed for the use with the pvlib.
The weather data set has to be a DataFrame with the following columns:
pvlib:
* ghi - global horizontal irradiation [W/m2]
* dni - direct normal irradiation [W/m2]
* dhi - diffuse horizontal irradiation [W/m2]
* temp_air - ambient temperature [°C]
* wind_speed - wind speed [m/s]
"""
from pvlib.location import Location
import pvlib.atmosphere
from pvlib.pvsystem import PVSystem
from pvlib.modelchain import ModelChain
import pandas as pd
import os
import pvlib
import logging
import sys
try:
import matplotlib.pyplot as plt
except ImportError:
plt = None
import pvcompare.cpv.inputs
import pvcompare.perosi.perosi
from pvcompare import area_potential
from pvcompare import check_inputs
from pvcompare import constants
from cpvlib import cpvlib
from pvcompare.cpv import apply_cpvlib_StaticHybridSystem
log_format = "%(asctime)s %(levelname)s %(filename)s:%(lineno)d %(message)s"
logging.basicConfig(stream=sys.stdout, level=logging.DEBUG, format=log_format)
[docs]def create_pv_components(
lat,
lon,
weather,
storeys,
year,
pv_setup=None,
plot=True,
user_inputs_pvcompare_directory=None,
user_inputs_mvs_directory=None,
psi_type="Chen",
normalization=True,
add_sam_si_module=None,
):
r"""
Creates feed-in time series for all surface types in `pv_setup` or 'pv_setup.csv'.
Reads 'pv_setup.csv', for each `surface_type` listed in `pv_setup`,
one PV time series is created with regard to the technology and its
orientation. All time series are normalized with the method specified in
`normalization` and stored as csv files in `user_inputs_mvs_directory/time_series`.
Further the area potential of the `surface_type` with regard to the building
parameters defined in 'building_parameters.csv' in `input_directory` is calculated
and the maximum installed capacity (nominal value) is calculated. Both parameters
are stored into `user_inputs_mvs_directory/csv_elements/energyProduction.csv`.
Further information for the cell parameter efficiency for "Chen" and "Korte" see
`psi_type <https://pvcompare.readthedocs.io/en/latest/model_assumptions.html#input-data>`_.
Parameters
----------
lat: float
Latitude of location
lon: float
Longitude of location
weather: :pandas:`pandas.DataFrame<frame>`
Hourly weather data frame with the columns:
time, latitude, longitude, wind_speed, temp_air, ghi, dhi, dni,
precipitable_water.
storeys: int
The number of storeys of a building.
pv_setup: dict or None
Specifies the PV technologies and their installation details used in the
simulation. The dictionary contains columns: surface_type, technology,
surface_azimuth, surface_tilt.
A tilt of 0 resembles a vertical orientation.
If `pv_setup` is None, it is loaded from the `input_directory/pv_setup.cvs`.
plot: bool
if true plots created pv times series
user_inputs_pvcompare_directory: str or None
Directory of the user inputs. If None,
`constants.DEFAULT_USER_INPUTS_PVCOMPARE_DIRECTORY` is used as user_inputs_pvcompare_directory.
Default: None.
user_inputs_mvs_directory: str or None
Directory of the multi-vector simulation inputs; where 'csv_elements/' is located. If None,
`constants.DEFAULT_USER_INPUTS_MVS_DIRECTORY` is used as user_inputs_mvs_directory.
Default: None.
psi_type: str
"Korte" or "Chen".
Default: "Chen"
normalization: bool
If True: Time series is normalized. Otherwise absolute time series is
returned. Default: True.
add_sam_si_module: dict
Dictionary with library ("CECMod" or "SandiaMod") as key and module name as value.
E.g. {"cecmod": "Canadian_Solar_Inc__CS5P_220M"}.
Returns
-------
None
"""
if pv_setup is None:
# read example pv_setup file
logging.info("loading pv setup conditions from input directory.")
if user_inputs_pvcompare_directory == None:
user_inputs_pvcompare_directory = (
constants.DEFAULT_USER_INPUTS_PVCOMPARE_DIRECTORY
)
data_path = os.path.join(user_inputs_pvcompare_directory, "pv_setup.csv")
pv_setup = pd.read_csv(data_path)
logging.info("Pv setup conditions successfully loaded.")
# check if all required columns are in pv_setup
if not all(
[
item in pv_setup.columns
for item in [
"surface_type",
"surface_azimuth",
"surface_tilt",
"technology",
]
]
):
raise ValueError(
"The file pv_setup does not contain all required columns"
"surface_azimuth, surface_tilt and technology."
)
# define time series directory
if user_inputs_mvs_directory is None:
user_inputs_mvs_directory = constants.DEFAULT_USER_INPUTS_MVS_DIRECTORY
time_series_directory = os.path.join(user_inputs_mvs_directory, "time_series")
# parse through pv_setup file and create time series for each technology
counter = 0
for i, row in pv_setup.iterrows():
j = row["surface_azimuth"]
k = row["surface_tilt"]
k = pd.to_numeric(k, errors="ignore")
if k == "optimal":
k = get_optimal_pv_angle(lat)
# check if timeseries already exists
# define the name of the output file of the time series
ts_csv = f"{row['technology']}_{j}_{k}_{year}_{lat}_{lon}.csv"
output_csv = os.path.join(time_series_directory, ts_csv)
if not os.path.isfile(output_csv):
logging.info(
"The timeseries does not exist yet and is therefore " "calculated."
)
if row["technology"] == "si":
time_series = create_si_time_series(
lat=lat,
lon=lon,
weather=weather,
surface_azimuth=j,
surface_tilt=k,
normalization=normalization,
add_sam_si_module=add_sam_si_module,
)
elif row["technology"] == "cpv":
time_series = create_cpv_time_series(
lat=lat,
lon=lon,
weather=weather,
surface_azimuth=j,
surface_tilt=k,
normalization=normalization,
)
elif row["technology"] == "psi":
time_series = create_psi_time_series(
lat=lat,
lon=lon,
year=year,
weather=weather,
surface_azimuth=j,
surface_tilt=k,
normalization=normalization,
)
else:
raise ValueError(
row["technology"],
"is not in technologies. Please " "choose 'si', 'cpv' or " "'psi'.",
)
# create time series directory if it does not exists
if not os.path.isdir(time_series_directory):
os.mkdir(time_series_directory)
# save time series into mvs_inputs
time_series.fillna(0, inplace=True)
time_series.to_csv(output_csv, header=["kW"], index=False)
logging.info(
"%s" % row["technology"] + " time series is saved as csv "
"into output directory"
)
else:
time_series = pd.read_csv(output_csv)
logging.info(
f"The timeseries {output_csv}"
"already exists and is therefore not calculated again."
)
# add "evaluated_period" to simulation_settings.csv
check_inputs.add_evaluated_period_to_simulation_settings(
time_series=time_series, user_inputs_mvs_directory=user_inputs_mvs_directory
)
if plot == True:
plt.plot(
time_series,
label=str(row["technology"]) + str(j) + "_" + str(k),
alpha=0.7,
)
plt.legend()
# calculate area potential
surface_type_list = [
"flat_roof",
"gable_roof",
"south_facade",
"east_facade",
"west_facade",
]
if row["surface_type"] not in surface_type_list:
raise ValueError(
"The surface_type in row %s" % i + " in pv_setup.csv"
" is not valid. Please choose from %s" % surface_type_list
)
else:
area = area_potential.calculate_area_potential(
storeys,
user_inputs_pvcompare_directory,
surface_type=row["surface_type"],
)
# calculate nominal value of the powerplant
nominal_value = nominal_values_pv(
technology=row["technology"],
area=area,
surface_azimuth=j,
surface_tilt=k,
psi_type=psi_type,
add_sam_si_module=add_sam_si_module,
)
# save the file name of the time series and the nominal value to
# mvs_inputs/elements/csv/energyProduction.csv
column_name = row["technology"]
# check if the technology appears multiple times
count_duplicates = (
pv_setup.groupby(["technology"]).size().reset_index(name="count")
)
for index, r in count_duplicates.iterrows():
if str(r["technology"]) == column_name and r["count"] > 1:
counter += 1
column_name = str(column_name) + str(counter)
check_inputs.add_parameters_to_energy_production_file(
technology=column_name,
ts_filename=ts_csv,
nominal_value=nominal_value,
user_inputs_mvs_directory=user_inputs_mvs_directory,
)
if plot == True:
plt.show()
[docs]def get_optimal_pv_angle(lat):
r"""
Calculates the optimal tilt angle depending on the latitude.
e.g. about 27° to 34° from ground in Germany.
The `pvlib <https://pvlib-python.readthedocs.io/en/stable/index.html>`_. uses
tilt angles horizontal=90° and up=0°. Therefore 90° minus
the angle from the horizontal.
Parameters
---------
lat: float
latitude
Returns
-------
int
Angle for optimal surface tilt of `lat`, rounded to zero decimal places.
"""
return round(lat - 15)
[docs]def set_up_system(technology, surface_azimuth, surface_tilt, add_sam_si_module=None):
r"""
Sets up pvlibPVSystems.
Initializes the `pvlib.PVSystem <https://pvlib-python.readthedocs.io/en/stable/pvsystem.html>`_
for the given type of technology and returns the system and the module parameters as a dictionary
Parameters
----------
technology: str
Possible technologies are: si, cpv or psi.
surface_azimuth: float
Surface azimuth of the module.
surface_tilt: float
Surface tilt of the module.
add_sam_si_module: dict
Dictionary with library ("CECMod" or "SandiaMod") as key and module name as value.
E.g. {"cecmod": "Canadian_Solar_Inc__CS5P_220M"}.
Returns
-------
Depending on `technology` returns the system and the module parameters
"""
if technology == "si":
if add_sam_si_module is None:
library = "cecmod"
module = "Aleo_Solar_S59y280"
else:
library, module = next(iter(add_sam_si_module.items()))
sandia_modules = pvlib.pvsystem.retrieve_sam(library)
sandia_module = sandia_modules[module]
# note that the inverter is not accounted for in the calculation of PV timeseries
cec_inverters = pvlib.pvsystem.retrieve_sam("cecinverter")
cec_inverter = cec_inverters["ABB__MICRO_0_25_I_OUTD_US_208__208V_"]
system = PVSystem(
surface_tilt=surface_tilt,
surface_azimuth=surface_azimuth,
module_parameters=sandia_module,
inverter_parameters=cec_inverter,
)
return system, sandia_module
elif technology == "cpv":
logging.debug("cpv module parameters are loaded from pvcompare/cpv/inputs.py")
mod_params_cpv = pvcompare.cpv.inputs.mod_params_cpv
mod_params_flatplate = pvcompare.cpv.inputs.mod_params_flatplate
static_hybrid_sys = cpvlib.StaticHybridSystem(
surface_tilt=surface_tilt,
surface_azimuth=surface_azimuth,
module_cpv=None,
module_flatplate=None,
module_parameters_cpv=mod_params_cpv,
module_parameters_flatplate=mod_params_flatplate,
modules_per_string=1,
strings_per_inverter=1,
inverter=None,
inverter_parameters=None,
racking_model="insulated",
losses_parameters=None,
name=None,
)
return (static_hybrid_sys, mod_params_cpv, mod_params_flatplate)
elif technology == "psi":
pass
else:
logging.warning(
f"{technology} is not in technologies. Please chose si, cpv or psi."
)
[docs]def create_si_time_series(
lat,
lon,
weather,
surface_azimuth,
surface_tilt,
normalization,
add_sam_si_module=None,
):
r"""
Calculates feed-in time series for a silicon PV module.
The si time series is created for a given weather data frame at a given
orientation for the flat plate module 'Aleo_Solar_S59y280'.
If `normalization` is True the time series is normalized.
Parameters
----------
lat: float
Latitude of the location.
lon: float
Longitude of the location.
weather: :pandas:`pandas.DataFrame<frame>`
surface_azimuth: float
Surface azimuth of the modules.
surface_tilt: float
Surface tilt of the modules.
normalization: bool
If True: Time series is normalized. Otherwise absolute time series is
returned.
add_sam_si_module: dict
Dictionary with library ("CECMod" or "SandiaMod") as key and module name as value.
E.g. {"cecmod": "Canadian_Solar_Inc__CS5P_220M"}.
Returns
-------
:pandas:`pandas.Series<series>`
Feed-in time series of silicon module.
"""
system, module_parameters = set_up_system(
technology="si",
surface_azimuth=surface_azimuth,
surface_tilt=surface_tilt,
add_sam_si_module=add_sam_si_module,
)
location = Location(latitude=lat, longitude=lon)
mc = ModelChain(
system,
location,
orientation_strategy=None,
aoi_model="ashrae",
spectral_model="first_solar",
temperature_model="sapm",
losses_model="pvwatts",
)
mc.run_model(weather=weather)
output = mc.dc
if normalization is False:
logging.info("Absolute si time series is calculated in kW.")
return output["p_mp"] / 1000
else:
logging.info("Normalized SI time series is calculated in kW/kWp.")
peak = get_peak(
technology="si",
module_parameters_1=module_parameters,
module_parameters_2=None,
)
return (output["p_mp"] / peak).clip(0)
[docs]def create_cpv_time_series(
lat, lon, weather, surface_azimuth, surface_tilt, normalization
):
r"""
Creates power time series of a hybrid CPV module.
The CPV time series is created for a given weather data frame `weather`
for the INSOLIGHT CPV module. If `normalization` is True the time
series is normalized.
Parameters
----------
lat : float
Latitude of the location for which the time series is calculated.
lon : float
Longitude of the location for which the time series is calculated.
weather : :pandas:`pandas.DataFrame<frame>`
DataFrame with time series for temperature `temp_air` in C°, wind speed
'wind_speed' in m/s, 'dni', 'dhi', and 'ghi' in W/m².
surface_azimuth : float
Surface azimuth of the modules (180° for south, 270° for west, etc.).
surface_tilt: float
Surface tilt of the modules (horizontal=90° and vertical=0°).
normalization: bool
If True: Time series is normalized. Otherwise absolute time series is
returned.
Returns
-------
:pandas:`pandas.Series<series>`
Power output time series of CPV module in W.
"""
system, mod_params_cpv, mod_params_flatplate = set_up_system(
technology="cpv", surface_azimuth=surface_azimuth, surface_tilt=surface_tilt
)
if normalization is False:
logging.info("Absolute CPV time series is calculated in kW.")
return (
apply_cpvlib_StaticHybridSystem.create_cpv_time_series(
lat, lon, weather, surface_azimuth, surface_tilt
)
/ 1000
)
else:
logging.info("Normalized CPV time series is calculated in kW/kWp.")
peak = get_peak(
technology="cpv",
module_parameters_1=mod_params_cpv,
module_parameters_2=mod_params_flatplate,
)
return (
apply_cpvlib_StaticHybridSystem.create_cpv_time_series(
lat, lon, weather, surface_azimuth, surface_tilt
)
/ peak
).clip(0)
[docs]def create_psi_time_series(
lat,
lon,
year,
surface_azimuth,
surface_tilt,
weather,
normalization,
psi_type="Chen",
):
r"""
Creates power time series of a perovskite-silicone (PSI) module.
The PSI time series is created for a given weather data frame
`weather`. If `normalization` is True the time series is normalized.
Further information for the cell parameter efficiency for "Chen" and "Korte" see
`psi_type <https://pvcompare.readthedocs.io/en/latest/model_assumptions.html#input-data>`_.
Parameters
----------
lat : float
Latitude of the location for which the time series is calculated.
lon : float
Longitude of the location for which the time series is calculated.
weather : :pandas:`pandas.DataFrame<frame>`
DataFrame with time series for temperature 'temp_air' in C°, wind speed
'wind_speed' in m/s, 'dni', 'dhi' and 'ghi' in W/m².
surface_azimuth : float
Surface azimuth of the modules (180° for south, 270° for west, etc.).
surface_tilt: float
Surface tilt of the modules. (horizontal=90° and vertical=0°)
psi_type : str
Defines the type of module of which the time series is calculated.
Options: "Korte", "Chen".
Default: "Chen".
normalization: bool
If True: Time series is normalized. Otherwise absolute time series is
returned.
Returns
-------
:pandas:`pandas.Series<series>`
Power output of PSI module in W (if parameter `normalized` is False) or
normalized power output of CPV module (if parameter `normalized` is
False).
"""
atmos_data = weather[
["ghi", "dhi", "dni", "wind_speed", "temp_air", "precipitable_water"]
]
number_rows = atmos_data["ghi"].count()
if normalization is False:
logging.info("Absolute PSI time series is calculated in kW.")
return (
pvcompare.perosi.perosi.create_pero_si_timeseries(
year,
lat,
lon,
surface_azimuth,
surface_tilt,
atmos_data=atmos_data,
number_hours=number_rows,
psi_type=psi_type,
)
/ 1000
)
else:
logging.info("Normalized CPV time series is calculated in kW/kWp.")
if psi_type == "Korte":
import pvcompare.perosi.data.cell_parameters_korte_pero as param1
import pvcompare.perosi.data.cell_parameters_korte_si as param2
elif psi_type == "Chen":
import pvcompare.perosi.data.cell_parameters_Chen_2020_4T_pero as param1
import pvcompare.perosi.data.cell_parameters_Chen_2020_4T_si as param2
peak = get_peak(
technology="psi", module_parameters_1=param1, module_parameters_2=param2,
)
output = pvcompare.perosi.perosi.create_pero_si_timeseries(
year,
lat,
lon,
surface_azimuth,
surface_tilt,
atmos_data=atmos_data,
number_hours=number_rows,
psi_type=psi_type,
)
# substract losses 45% in order to get to a realistic performance ratio
output = output - output * 0.45
return (output / peak).clip(0)
[docs]def nominal_values_pv(
technology, area, surface_azimuth, surface_tilt, psi_type, add_sam_si_module=None
):
"""
calculates the maximum installed capacity for each pv module.
The nominal value for each PV technology is constructed by the size of
the module, its peak power and the total available area. It is given in
the unit of kWp. The nominal value functions as a limit for the potential
maximum installed capacity of PV in the energy system optimization.
Further information for the cell parameter efficiency for "Chen" and "Korte" see
`psi_type <https://pvcompare.readthedocs.io/en/latest/model_assumptions.html#input-data>`_.
Parameters
----------
technology: str
Possible values are: si, cpv or psi.
area: float
total available surface area.
surface_azimuth: float
Surface azimuth of the modules.
surface_tilt: float
Surface tilt of the modules.
psi_type : str
Defines the type of module of which the time series is calculated.
Options: "Korte", "Chen".
add_sam_si_module: dict or None
Dictionary with library ("CECMod" or "SandiaMod") as key and module name as value.
E.g. {"cecmod": "Canadian_Solar_Inc__CS5P_220M"}.
Note that the SI module is only considered if there is the technology "SI" in
Returns
-------
nominal_value: int
The rounded possible installed capacity for an area.
"""
if technology == "si":
system, module_parameters = set_up_system(
technology=technology,
surface_azimuth=surface_azimuth,
surface_tilt=surface_tilt,
add_sam_si_module=add_sam_si_module,
)
peak = get_peak(
technology, module_parameters_1=module_parameters, module_parameters_2=None,
)
module_size = module_parameters["A_c"]
nominal_value = round((area / module_size) * peak) / 1000
elif technology == "cpv":
system, mod_params_cpv, mod_params_flatplate = set_up_system(
technology=technology,
surface_azimuth=surface_azimuth,
surface_tilt=surface_tilt,
)
peak = get_peak(
technology,
module_parameters_1=mod_params_cpv,
module_parameters_2=mod_params_flatplate,
)
module_size = mod_params_cpv["Area"]
nominal_value = round((area / module_size) * peak) / 1000
elif technology == "psi":
if psi_type == "Korte":
import pvcompare.perosi.data.cell_parameters_korte_pero as param1
import pvcompare.perosi.data.cell_parameters_korte_si as param2
elif psi_type == "Chen":
import pvcompare.perosi.data.cell_parameters_Chen_2020_4T_pero as param1
import pvcompare.perosi.data.cell_parameters_Chen_2020_4T_si as param2
# calculate peak power with 5 % CTM losses nad 5 % cell connection losses
peak = get_peak(
technology, module_parameters_1=param1, module_parameters_2=param2,
)
module_size = param1.A / 10000 # in m^2
nominal_value = round((area / module_size) * peak) / 1000
logging.info(
"The nominal value for %s" % technology
+ " is %s" % nominal_value
+ " kWp for an area of %s" % area
+ " qm."
)
return nominal_value
[docs]def get_peak(technology, module_parameters_1, module_parameters_2):
r"""
This function returns the peak value for the given `technology`.
Parameter
---------
technology: str
Possible values are: si, cpv or psi.
module_parameters_1: dict
Module parameters of cell 1 or module.
module_parameters_2: dict
If `technology` is 'si', set parameter to None
Returns
--------
peak: float
Peak value of the `technology`.
"""
if technology == "si":
peak = module_parameters_1["I_mp_ref"] * module_parameters_1["V_mp_ref"]
return peak
elif technology == "cpv":
peak = module_parameters_1["p_mp"] + module_parameters_2["p_mp"]
return peak
elif technology == "psi":
# calculate peak power with 10 % CTM losses
peak = (
module_parameters_1.p_mp
+ module_parameters_2.p_mp
- (module_parameters_1.p_mp + module_parameters_2.p_mp) * 0.1
)
return peak
def add_pv_timeseries(
add_pv_timeseries,
storeys,
user_inputs_mvs_directory,
user_inputs_pvcompare_directory,
):
r"""
Adds PV time series of user to the simulations inputs.
This function calculates the maximum capacity and inserts the time series filename
and the maximum capacity into 'user_inputs_mvs_directory/csv_elements/energyProduction.csv'.
Parameter
----------
add_pv_timeseries: dict or None
Dictionary with {"PV1" : ["filename": >path_to_time_series< , "module_size": >module_size in m²<,
"module_peak_power": >peak power of the module in kWp<, "surface_type": >surface_type for PV installation<],
"PV2" : [...], ...}. You can add more than one module time series by defining more PV-keys.
The PV time series itself needs to be a normalized hourly time series in kW/kWp
(normalized by the peak power of the module). The surface_type can be one of: [
"flat_roof", "gable_roof", "south_facade", "east_facade", "west_facade"].
Note that you need to add more specific PV parameters of your module (name, costs, lifetime etc.) in
``user_inputs_mvs_directory/csv_elements/energyProduction.csv``. The columns in ``energyProduction.csv``
should be named "PV"+ key (e.g. "PV SI1" if your key is "SI1").
When providing your own time series, ``overwrite_pv_parameters`` in :py:func:`~.main.apply_pvcompare` should be
set to ``False``. When ``add_pv_timeseries`` is used, the ``pv_setup.csv`` is disregarded.
storeys: int
number of storeys for which the demand is calculated.
user_inputs_mvs_directory: str or None
Directory of the mvs inputs; where 'csv_elements/' is located. If None,
`constants.DEFAULT_USER_INPUTS_MVS_DIRECTORY` is used as user_inputs_mvs_directory.
Default: None.
user_inputs_pvcompare_directory: str or None
If None, `constants.DEFAULT_USER_INPUTS_PVCOMPARE_DIRECTORY` is used
as user_inputs_pvcompare_directory.
Default: None.
Returns
-------
None
"""
for key in add_pv_timeseries.keys():
# check if PV timeseries exists
if not os.path.isfile(add_pv_timeseries[key]["filename"]):
raise ValueError(
"The PV time series you have specified does not exist. "
"Please check your input or set `add_pv_timeseries` to None "
"in order to use the default pvcompare methods."
)
return
pv_timeseries = pd.read_csv(
add_pv_timeseries[key]["filename"], index_col=0, header=None
)
# add "evaluated_period" to simulation_settings.csv
check_inputs.add_evaluated_period_to_simulation_settings(
time_series=pv_timeseries,
user_inputs_mvs_directory=user_inputs_mvs_directory,
)
area = area_potential.calculate_area_potential(
storeys,
user_inputs_pvcompare_directory,
surface_type=add_pv_timeseries[key]["surface_type"],
)
nominal_value = round(
(area / add_pv_timeseries[key]["module_size"])
* add_pv_timeseries[key]["module_peak_power"]
)
check_inputs.add_parameters_to_energy_production_file(
technology=key,
ts_filename=add_pv_timeseries[key]["filename"],
nominal_value=nominal_value,
user_inputs_mvs_directory=user_inputs_mvs_directory,
)